Difference between revisions of "Eth8x8 Control Interface"

From eMDeeWiki
Jump to navigationJump to search
Line 3: Line 3:
 
<li>The Eth8x8 shall listen for TCP/IP connections on IP port number 33001</li>
 
<li>The Eth8x8 shall listen for TCP/IP connections on IP port number 33001</li>
 
<li>A maximum of 3 clients can simultaneously connect to the Control Interface port</li>
 
<li>A maximum of 3 clients can simultaneously connect to the Control Interface port</li>
 +
<li>All elements of each packet shall be in network byte order</li>
 
</ul>
 
</ul>
  
Line 12: Line 13:
 
<li>Each element of the Data Request Packet is a 16 bit integer</li>
 
<li>Each element of the Data Request Packet is a 16 bit integer</li>
 
<li>The first 16 bit word of the packet represents the unique identifier and must be equal to 0x100</li>
 
<li>The first 16 bit word of the packet represents the unique identifier and must be equal to 0x100</li>
<li>All elements of the packet shall be in network byte order</li>
 
 
<li>A Status Packet with the requested data will be sent back to the client in response to each Data Request</li>
 
<li>A Status Packet with the requested data will be sent back to the client in response to each Data Request</li>
 
</ul>
 
</ul>
Line 38: Line 38:
 
<li>Each element of the Mixer Control Packet is a 16 bit integer</li>
 
<li>Each element of the Mixer Control Packet is a 16 bit integer</li>
 
<li>The first 16 bit word of the packet represents the unique identifier and must be equal to 0x808</li>
 
<li>The first 16 bit word of the packet represents the unique identifier and must be equal to 0x808</li>
<li>All elements of the packet shall be in network byte order</li>
 
 
</ul>
 
</ul>
  

Revision as of 16:05, 28 February 2019

Data can be passed from a client to an Eth8x8 through the Eth8x8 Control Interface. Packets are sent from the client to the Eth8x8 through a TCP/IP port. The following rules apply:

  • The Eth8x8 shall listen for TCP/IP connections on IP port number 33001
  • A maximum of 3 clients can simultaneously connect to the Control Interface port
  • All elements of each packet shall be in network byte order

The following sections define the packets that can be sent to the Eth8x8


Data Request

  • Each element of the Data Request Packet is a 16 bit integer
  • The first 16 bit word of the packet represents the unique identifier and must be equal to 0x100
  • A Status Packet with the requested data will be sent back to the client in response to each Data Request


Byte Offset Element
0 0x100
2 Unique Identifier of Requested Data


Mixer Control Packet 8 input x 8 output

  • Each element of the Mixer Control Packet is a 16 bit integer
  • The first 16 bit word of the packet represents the unique identifier and must be equal to 0x808


Byte Offset Element
0 0x808
2 In 1 to Out 1
4 In 1 to Out 2
6 In 1 to Out 3
8 In 1 to Out 4
10 In 1 to Out 5
12 In 1 to Out 6
14 In 1 to Out 7
16 In 1 to Out 8
18 - 32 In 2 to Out 1
...
In 2 to Out 8
34 - 48 In 3 to Out 1
...
In 3 to Out 8
50 - 64 In 4 to Out 1
...
In 4 to Out 8
66 - 80 In 5 to Out 1
...
In 5 to Out 8
82 - 96 In 6 to Out 1
...
In 6 to Out 8
98 - 112 In 7 to Out 1
...
In 7 to Out 8
114 - 128 In 8 to Out 1
...
In 8 to Out 8